Description
1756-DHRIO AB罗克韦尔变频器原理
1756-DHRIO说明书AB罗克韦尔变频器原理
_集成PID控制器可以自动调节输出频率和过程变量。
三个可编程跳频段防止逆变器在共振频率下连续运行,以避免机械损伤
可选风机/泵曲线,为离心风机和泵负载提供电压降低模式AB罗克韦尔1756-EN2TR全新原装_的休眠功能,当系统需求降低到预设标准时,自动关闭机器;当系统需求增加时,机器自动启动。
在一些无人操作的环境中,当系统关闭后再恢复时,逆变器会自动重启操作
◆Freeze / Fire和Purge等特殊输入可直接连接到消防等应急安全系统
1756-IB16原理RS485通信集成到逆变器中
内置的modbus rtu和约翰逊sys n2协议是可选参数,不需要额外的软件和硬件支持来驱动串行接口(dsi)通信模块和配件AB罗克韦尔1756-EN2TRXT*价格
◆使用DriveExplorer和DriveTools轻松编程,监控和控制驱动器
_整套变频器符合UL标准,提高了安装的灵活性,允许变频器直接安装在开关柜内。
该变频器的断路器和接触器旁路设备,只需通过简单的装配,就可以通过组合操作面板、控制器、通信和预装电源选择启动。
AB罗克韦尔1756-EN2TR全新原装◆全套变频器旁路接触器提供三对接触器触点。当变频器处于旁路模式时,可以测试变频器的功能并隔离变频器。
1756-DHRIO AB罗克韦尔变频器原理
1756-DHRIO Specification AB Rockwell inverter principle
_ Integrated PID controller can automatically adjust the output frequency and process variables.
Three programmable band hops prevent the inverter from operating continuously at resonant frequencies to avoid mechanical damage
Optional fan/pump curve provides a voltage reduction mode AB Rockwell 1756-EN2TR new original _ sleep function for centrifugal fan and pump load, which automatically shuts down the machine when the system demand decreases to a preset standard; When the system demand increases, the machine starts automatically.
In some unmanned environments, when the system is shut down and then recovered, the inverter automatically restarts
◆ Special inputs such as Freeze/Fire and Purge can be directly connected to emergency safety systems such as fire
1756-IB16 Principle RS485 communication is integrated into the inverter
The built-in modbus rtu and Johnson sys n2 protocols are optional parameters and do not require additional software and hardware support to drive Serial Interface (dsi) communication modules and accessories AB Rockwell 1756-EN2TRXT* Price
◆ Easily program, monitor and control drives with DriveExplorer and DriveTools
_ The complete inverter complies with UL standards, increasing installation flexibility and allowing the inverter to be installed directly in the switch cabinet.
The inverter’s circuit breaker and contactor bypass devices can be activated selectively through a combination of operating panels, controllers, communications and pre-installed power supplies with a simple assembly.
AB Rockwell 1756-EN2TR New original ◆ Complete inverter bypass contactor provides three pairs of contactor contacts. When the inverter is in bypass mode, the function of the inverter can be tested and the inverter can be isolated.
- 购买咨询热线/Phone:18859254943
- 邮箱/Email:sales@ygdcs.com