Description
3500-33 6通道继电模块是一个全高模块
3500/33 Bently Nevada技术规格
6通道继电模块是一个全高模块,它提供16个继电器输出。你可以放置任意数量的16-右侧任何插槽中的通道继电器模块瞬态数据接口模块。16通首继电器模块的每人输出可以是独立编程以执行表决逻辑,模块的每人继电器都包括报警区动逻,报警动逻的编程使用AND和逻and可以使用以下内容:n报警输入(警报和危险状态]不太好来自任何监控通道的n个单独的测量变量或者机架中监视器通道的任意组合您可以使用3500框架对最取动进行编程配置软性。1 16通道继电器模块需要3500桂架配置,版本3.3或更高版本,16通道继电器模块需要3500数采集软性,2.40或更高版本,16通道继电器模块需要3500数据显示软件,版本=1.40或更高,n以倍数订购时认证选项(02),3500显示器是通过2区标准认证,包括ATEX和北美地区,n 2区标准规定增加更高电压下的间距要求,16通道继电器模块不满足这些间距要求,因此,与倍数一起订购的模块批准选项仅限于较低
丰乐比那些与其他批准选项。n使用更高的电乐违反了与以下相关的危险区域证书多重松准选项,北美第2部分标准与仅限CSA的批准相关联选项/-01降级为30Vrms符合61010-1型式试验要求,n如16通道继电器模块是功能安全(SIL)系统功能安全证书要求受限电压,更高的电压不会允许用于功能安全(SIL)系统。
3500-33 6通道继电模块是一个全高模块
The 6-channel relay module is a full-height module that provides 16 relay outputs. You can place any number of 16- on the right of any slot in the channel relay module transient data interface module. The per-person output of the 16-head relay module can be independently programmed to execute voting logic, and the per-person relays of the module include alarm area logic, Programming use of Alarm logic AND and Logic can use the following :n Alarm inputs (alarm and danger states) are not good n individual measurement variables from any monitor channel or any combination of monitor channels in the rack You can program the most fetch using the 3500 frame configuration flexibility. 1 16 channel relay module requires 3500 bay configuration, version 3.3 or higher, 16 channel relay module requires 3500 data acquisition soft, version 2.40 or higher, 16 channel relay module requires 3500 data display software, version =1.40 or higher, n in multiples when ordering authentication options (02), The 3500 monitor is certified to Zone 2 standards, including ATEX and North America, and the Zone n2 standard specifies increased pitch requirements at higher voltages. 16-channel relay modules do not meet these pitch requirements, so the module approval options ordered with multiples are limited to lower levels
Funle compares those with other approved options. n The use of higher electronic music violates the Hazardous Area Certificate Multiple release option, the North American Part 2 standard associated with the approval of the CSA only option /-01 to be downgraded to 30Vrms to meet the 61010-1 type test requirements, n such as the 16-channel relay module is a functional safety (SIL) system with a functional safety certificate requiring limited voltage, Higher voltages will not be allowed for functional safety (SIL) systems.
- 购买咨询热线/Phone:18859254943
- 邮箱/Email:sales@ygdcs.com
- 地址:成都高新区天益街北巷52号附14号2层